Operation effect
|
Actual operating parameters |
|
|
Standard flue gas volume |
380000Nm³/h (work condition 820000m3/h) |
|
Flue gas temperature |
310℃ |
|
Inlet dust loading |
100g/Nm³ |
|
Inlet NOx concentration |
500mg/Nm³ |
|
Outlet dust loading |
<10mg/Nm³ |
|
Outlet NOx concentration |
<30mg/Nm³ |
|
Ammonia slip |
<2.5mg/Nm3 |
|
Integrated device system resistance |
<1000Pa |